Utilize este identificador para referenciar este registo: http://hdl.handle.net/10400.1/5858
Título: Time, time-frequency and displacement-frequency analysis of embolic signals
Autor: Leiria, A.
Moura, M. M. M.
Ruano, M. Graça
Evans, D. H.
Palavras-chave: Acoustics
Biomedical signal processing
Blood flow
Spectral analysis
Data: 1-Dez-2005
Editora: IEEE
Resumo: The characteristics of a new method, the displacement-frequency representation, prompted the study of its use for the analysis of embolic blood flow signals. This paper reports the comparison of displacement-frequency and time-frequency methods with time domain methods, in the characterization of emboli. The study was performed on clinical signals derived from gaseous and particulate embolic events. The results obtained with the different approaches were compared. The conclusions of this study provide encouragement for the use of displacement-frequency domain processing for this kind of analysis.
Peer review: yes
URI: http://hdl.handle.net/10400.1/5858
ISBN: 0-7803-9030-X
Aparece nas colecções:FCT2-Artigos (em revistas ou actas indexadas)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2005_Time_Wisp.pdf319,75 kBAdobe PDFVer/Abrir    Acesso Restrito. Solicitar cópia ao autor!


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 