- Anode heel effect attenuation in lumbar spine radiography: can the use of aluminium filters improve clinical practice of radiographers?Publication . Ribeiro, Luís Pedro; Abrantes, António; Lesyuk, Oksana; Dores, Rúben; Sousa, Patrick; Rodrigues, Sónia; Almeida, Rui; Azevedo, Kevin; Soares, Joana; Aleixo, JoãoPurpose: The aim of this study was to design an aluminiumbased fi lter to reduce the anode heel eff ect in lumbar spine radiographs. Methods: Initially, lumbar spine examinations were observed in a public imaging department to determine standard exposure parameters. Then, the characterization of the anode heel eff ect was made using the Unfors Xi R/F detector and, based on the data collected, aluminium fi lters were designed with a wedge shape and thicknesses ranging from 0.1 to 4.0 mm. The assessment of the entrance skin dose (ESD) reduction was performed on the anthropomorphic phantom with and without fi lters, using the universal dosimeter UNIDOS E equipped with an ionization chamber. Finally, the image quality assessment was performed with the Pehamed Phantom Digrad A+K and image quality surveys were applied to radiographers and radiologists. Results and Discussion: Uniformity of the beam was achieved, especially with fi lter number 2, which presents a signifi cant variation of 9% between the cathodic and anodic side. This fi lter contributes to ESD reduction of 35% and 36% for AP and lateral projection, respectively. Also, according to radiographers and radiologists, it improves the image quality of lumbar spine radiography. Conclusion: The use of aluminium fi lters can be advantageous in the clinical practice of radiographers when performing lumbar spine radiographs since it allows the standardization of the anode heel eff ect, reduces the radiation dose to the patient and does not compromise image quality.
- Avaliação da dose em recém-nascidos numa unidade neonatalPublication . Ribeiro, Luís; Rodrigues, Sónia Isabel do Espírito Santo; Sousa, Patrick; Abrantes, António; Sousa, Liliana; Almeida, Rui; Azevedo, Kevin; Pinheiro, JoãoObjetivo: Avaliar a dose a que estão sujeitos os recém-nascidos internados numa Unidade de Cuidados Intensivos Neonatais (UCIN) durante a realização de radiografias em incidência AP ao tórax e comparar os valores obtidos da Dose à Entrada da Pele (DEP), tanto com os recomendados internacionalmente para os recém-nascidos como com os resultados de estudos anteriores. Pretende-se também verificar se as doses utilizadas se encontram abaixo dos valores recomendados e se os pacientes se apresentam ou não em risco face às radiações ionizantes a que foram submetidos. Metodologia: Foi utilizado um equipamento de radiologia convencional móvel Siemens Mobilett XP Hybrid, uma Unidade base Unfors Xi com detetor Xi R/F e uma incubadora Dräger Incubator 8000 SC. Previamente ao início do estudo foi realizado o controlo de qualidade do equipamento inicialmente referido utilizando o detetor Unfors Xi. Realizaram-se exposições nas quais foram medidas a energia do feixe primário (kVp), Débito de Dose (Do) e a Exposição (X), a uma DFF de 1 metro. Foram também realizadas medições com uma DFF de 1m, com e sem incubadora, de modo a determinar a percentagem de atenuação do feixe de raios-x, exercida pelo material de polimetil-metacrilato (PMMA) com 5mm de espessura, que reveste a incubadora. Durante 3 meses foram recolhidos e registados os dados relativos aos parâmetros de exposição (kVp e mAs) utilizados na UCIN na realização de 24 radiografias ao tórax, com o intuito de calcular a sua média e o percentil 75, para determinação da DEP em função da metodologia selecionada. Foi também efetuada uma pesquisa que englobou um período temporal de 16 meses para recolher dados empíricos relativos ao número de crianças internadas na UCIN que realizaram exames radiológicos e outras informações como o peso corporal, tempo de gestação, dias de vida aquando da realização do exame imagiológico, tempo de internamento e a indicação clínica. Os recém-nascidos foram divididos em 3 grupos distintos consoante o seu peso: [0-1000g], ]1000-2000g] e [>2000g]. Resultados: Ao longo dos 16 meses foram realizadas 182 incidências AP do Tórax num total de 89 crianças, 68 das quais eram prematuras e 21 não prematuras (>37 semanas de gestação). Cada criança realizou, em média, cerca de duas radiografias ao tórax. A média total de peso foi de 2009,89g, sabendo-se que cerca de 75% das crianças apresentavam um peso inferior a 2.5 Kg. O valor mínimo registado foi de 675g e o máximo de 4730g. Aproximadamente 75% das crianças tinham menos de 48 horas de vida aquando da realização do exame imagiológico. Os valores de DEP resultantes da média foram de 28,81 µGy para uma dff de 100 cm e 14,53 µGy para uma dff de 128 cm, e os resultantes do percentil 75 de 23,35 µGy para uma dff de 100 cm e 14,25 µGy para uma dff de 128 cm. Conclusão: De acordo com o objetivo preconizado, optou-se por utilizar o cenário mais pessimista, ou seja, os valores de DEP (média e percentil 75) obtidos a 100cm. Ao comparar a DEP do percentil 75 (23,35 µGy), concluiu-se que estes valores não excederam os limites exigidos de 80 µGy para a European Commission (1996) nem os 50 µGy segundo a National Radiological Protection Board (2000). Relativamente à comparação com os resultados de outros estudos, utilizaram-se os valores da DEP da média 28,81 µGy. Verificou-se que estes valores apenas ultrapassaram os resultados obtidos no estudo “Radiology in the neonatal intensive care unit: dose reduction and image quality” que teve uma DEP de 20.0 µGy. Assim, a DEP nos recém-nascidos está dependente de vários fatores entre os quais, as variações dos parâmetros técnicos utilizados, a distância foco-filme e a atenuação do feixe de raios-x exercida pelo material que reveste a incubadora.
- Evaluation of the patient exposure dose during ERCP Fluoroscopy guided proceduresPublication . Granadas, Marisa; Rodrigues, Sónia; Sousa, Patrick; Lesyuk, Oksana; Vicente, Bianca; Almeida, Rui; Azevedo, Kevin; Ribeiro, Luís; Abrantes, AntónioEndoscopic retrograde cholangiopancreatography (ERCP) is a diagnostic/therapeutic fluoroscopy guided procedure that includes upper gastrointestinal endoscopy allowing the treatment of the bile and pancreatic ducts pathologies. Currently, ERCP is mostly used in therapy, which turns in to longer procedures, with potential higher doses of ionizing radiation to the patient and due to the cancer development risk it's relevant to evaluate dose exposure during ERCP. The International Atomic Energy Agency (IAEA) defined the mean dose area product (DAP) for ERCP diagnostic procedures as 15 Gy.cm2 and mean...
- Exposição à radiação secundária na realização de estudos radiológicos a pacientes intransportáveisPublication . Abrantes, António; Sousa, Patrick; Ribeiro, Luís; Rodrigues, Sónia Isabel do Espírito Santo; Rebelo, Carina; Azevedo, Kevin; Almeida, Rui; Pinheiro, JoãoObjetivo: Considerando que numa unidade hospitalar existem serviços onde estão internados pacientes que não se podem deslocar, sendo-lhes frequentemente prescritos estudos radiológicos, o objetivo deste trabalho consistiu em quantificar a exposição à radiação secundária na realização de radiogramas a doentes intransportáveis. Desta forma, pretendeu-se compreender, de acordo com a legislação em vigor e o state-of-art, que medidas devem ser adotadas/corrigidas no sentido de proteger adequadamente os profissionais, os pacientes que se submetem ao exame e também aqueles que inevitavelmente têm de permanecer na sala onde é realizado o exame. Metodologia: Foi efetuado o levantamento das condições técnicas utilizadas no exame em doentes intransportáveis numa amostra de 199 exames, o que possibilitou a determinação dos parâmetros de referência. Estes parâmetros foram também utilizados no controlo de qualidade do equipamento móvel de Radiologia Convencional, efetuado com um detetor semicondutor. Posteriormente, e uma vez que a radiologia utiliza radiação ionizante, o que condiciona todo e qualquer estudo experimental no ser humano, procedemos à simulação, e medição da radiação dispersa, reproduzindo as condições registadas no levantamento prévio, para a incidência ântero-posterior do tórax e para a incidência tangencial do abdómen (por serem as mais realizadas), com um fantôma antropomórfico de corpo inteiro em decúbito dorsal e semi-sentado. Mediu-se a radiação dispersa em função da voltagem e do produto corrente-tempo com um dosímetro de radiação X e gama. Fixando esses parâmetros, mediu-se a radiação dispersa em função do ângulo, altura e distância do dosímetro, para as incidências do tórax. A variação da radiação dispersa em função do ângulo foi também medida para a incidência do abdómen. Resultados: Para distâncias inferiores a 1 m, o Limite de dose estabelecido pela legislação para os trabalhadores expostos não é ultrapassado (12 mSv/ano) mas para os membros do público já será (2 mSv/ano). Os trabalhadores expostos devem utilizar dosímetro individual e no alcance do feixe primário devem usar medidas de proteção e posicionar-se atrás da ampola do equipamento móvel. De acordo com as três configurações utilizadas, resultantes do levantamento das características do feixe conjugadas com a tipologia de exames mais solicitados, obtivemos curvas de isodose que nos permitem determinar as distância e localização mais seguras, bem como, determinar o tipo de proteção radiológica que devemos utilizar nos indivíduos expostos. Conclusão: É fundamental utilizar medidas de proteção radiológicas para não ultrapassar os limites de dose e cumprir com o princípio ALARA, para melhor proteger os profissionais, os pacientes e o público em geral, entenda-se, outros pacientes que inevitavelmente têm de permanecer no mesmo espaço.
- Scatter radiation exposure during mobile X-Ray examinationsPublication . Abrantes, António; Rebelo, Carina; Sousa, Patrick; Rodrigues, Sónia; Almeida, Rui; Pinheiro, João; Azevedo, Kevin; Ribeiro, Luís PedroThe main goal of this research was to quantify scatter radiation exposure from mobile x-ray examinations. The simulation consisted of reproducing the technical conditions for the chest anteroposterior (AP) examination in supine and semi-supine positions as well as for the abdomen tangential projection, using a full body anthropomorphic phantom and an x-ray detector. For distances above 1m, the national dose limits for exposed workers is not exceeded (12 mSv/year), but for members of the public it is exceeded (2 mSv/year). Therefore, exposed workers should use a personal dosimeter, employ protective measures and stand behind the mobile equipment. The use of ionising radiation for diagnostic and treatment purposes has increased due to the development of new equipment and easier access to radiologic examinations.
- Study of scattered radiation during fluoroscopy in hip surgeryPublication . Lesyuk, Oksana; Sousa, Patrick; Rodrigues, Sónia Isabel do Espírito Santo; Abrantes, António; Almeida, Rui; Pinheiro, João; Azevedo, Kevin; Ribeiro, LuísObjetivo: Medir a intensidade da dose de radiação espalhada em diferentes posições simulando uma intervenção cirúrgica no quadril. Materiais e Métodos: Simulou-se uma intervenção cirúrgica no quadril com apoio da fluoroscopia para estudar a distribuição da radiação espalhada no bloco operatório. Para simular o paciente foi utilizado um simulador antropomórfico de corpo inteiro e para medir a radiação utilizou-se um detector específico para medir raios X. Realizaram-se incidências com um equipamento de raios X tipo arco em C móvel, em modo de escopia contínua, com a ampola a 0° (configuração 1) e a 90° (configuração 2). Os parâmetros operacionais utilizados (voltagem, corrente, tempo de exposição) foram determinados por meio de um estudo estatístico resultante da observação de cirurgias ortopédicas de quadril. Resultados: Em todas as medições observaram-se exposições mais elevadas na configuração 2. Nas medições em função da altura, observaram-se os valores máximos da taxa de dose de 1,167 (± 0,023) µSv/s e 2,278 (± 0,023) µSv/s nas configurações 1 e 2, respectivamente, correspondendo à altura do tórax dos profissionais. No estudo em torno do paciente os valores máximos registraramse na posição ocupada pelo médico cirurgião. Conclusão: Concluiu-se que a exposição à radiação dos profissionais é baixa, podendo ainda ser reduzida mediante o uso de equipamentos de proteção individual