Repository logo
 
Publication

Simplified model of finned-tube heat exchangers based on the effectiveness method and calibrated with manufacturer and experimental data

dc.contributor.authorRuivo, Celestino
dc.contributor.authorDominguez-Munoz, Fernando
dc.contributor.authorCosta, Jose J.
dc.date.accessioned2019-11-20T15:07:52Z
dc.date.available2019-11-20T15:07:52Z
dc.date.issued2017-01
dc.description.abstractA simplified model for predicting the overall thermal performance of finned-tube heat exchangers considering water and air as hot and cold fluids, respectively, is investigated. The model is based on the classical epsilon-NTU method and the thermal convective resistance in each fluid is estimated after conventional type (Nusselt number) empirical correlations. The model is calibrated with catalogue data of a heating coil. Calibrations of six families of model versions are performed by using different numbers of operating cases ranging from 2 to 320, some of them taking into account the influence of varying properties. The calibrated versions are tested for operating cases listed in the catalogue and the best performing versions are identified, such as the one calibrated with 24 cases and taking into account the effect of the fluid properties, which provided better accuracy than the versions calibrated in previous works. A test of the method robustness is conducted regarding the influence of the initial guessed values of the thermal resistances on the calibration procedure. The validity of the component model is further investigated by using a set of published experimental data for an automotive radiator covering ranges of practical interest of the mass flow rates of both air and water streams, and some versions providing excellent results are identified. The model based on a suitable version previously calibrated and tested is a promising procedure for the modular component simulation of finned-tube heat exchangers, when used as air conditioning heating coils or in other particular applications. (C) 2016 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.applthermaleng.2016.09.115
dc.identifier.issn1359-4311
dc.identifier.urihttp://hdl.handle.net/10400.1/13257
dc.language.isoeng
dc.peerreviewedyes
dc.publisherPergamon-Elsevier Science Ltd
dc.subjectAir-flow maldistribution
dc.subjectPlate-fin
dc.subjectTransfer coefficients
dc.subjectFluid-flow
dc.subject3D Cfd
dc.subjectPerformance
dc.subjectCoils
dc.subjectSide
dc.titleSimplified model of finned-tube heat exchangers based on the effectiveness method and calibrated with manufacturer and experimental data
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage352
oaire.citation.startPage340
oaire.citation.titleApplied Thermal Engineering
oaire.citation.volume111
person.familyNameRuivo
person.givenNameCelestino
person.identifier.ciencia-id9A17-9D4B-A0A9
person.identifier.orcid0000-0002-3915-0554
person.identifier.ridI-7712-2015
person.identifier.scopus-author-id14020628300
rcaap.rightsrestrictedAccess
rcaap.typearticle
relation.isAuthorOfPublicationc0c1a39a-793a-4569-a026-b08f0bc7dde4
relation.isAuthorOfPublication.latestForDiscoveryc0c1a39a-793a-4569-a026-b08f0bc7dde4

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
13257.pdf
Size:
822.09 KB
Format:
Adobe Portable Document Format

Collections