Repository logo
 
Publication

Testing the reliability of CT scan‐based dental wear magnitude scoring

dc.contributor.authorGodinho, Ricardo Miguel
dc.contributor.authorGonƧalves, CƩlia
dc.date.accessioned2021-09-02T09:49:46Z
dc.date.available2021-09-02T09:49:46Z
dc.date.issued2021-07
dc.description.abstractObjectives: Digital models are now frequently used in biological anthropology (bio anthropology) research. Despite several studies validating this type of research, none has examined if the assessment of dental wear magnitude based on Computerized Tomography (CT) scans is reliable. Thus, this study aims to fill this gap and assess if dental wear magnitude scoring based on CT scans provides results consistent with scoring based on direct observation of the physical specimens. Materials and Methods: Dental wear magnitude from 412 teeth of 35 mandibles originating from the Portuguese Muge and Sado Mesolithic shell-middens was scored. The mandibles were also CT scanned and visualized using 3D Slicer. CT scan based scoring of dental wear magnitude was then undertaken. Two scoring rounds were undertaken for each observation method (totaling four scoring rounds) and an intra-observer error test was performed. The averaged results of the two observation methods were compared via boxplots with paired cases. Results: Intra-observer error was negligible and non-significant. Scoring results are comparable between the two observation methods. Notwithstanding, some differ ences were found, in which CT scan assessment generally overestimates dental wear when compared to direct observation. Discussion: Our results generally validate the use of CT scans in studies of dental wear magnitude. Notwithstanding several caveats relating to CT scanning and visualization limitations should be considered to avoid over or under-estimation of dental wear.pt_PT
dc.description.sponsorshipALG-01-0145-FEDER-29680, 57/2016/CP1361/CT0029pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1002/ajpa.24374pt_PT
dc.identifier.eissn1096-8644
dc.identifier.urihttp://hdl.handle.net/10400.1/16917
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherWileypt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectBiological anthropologypt_PT
dc.subjectCT scanspt_PT
dc.subjectDigitizationpt_PT
dc.subjectTeethpt_PT
dc.subjectVirtual anthropologypt_PT
dc.titleTesting the reliability of CT scan‐based dental wear magnitude scoringpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.titleAmerican Journal of Physical Anthropologypt_PT
person.familyNameGodinho
person.familyNameGonƧalves
person.givenNameRicardo Miguel
person.givenNameCƩlia
person.identifier.ciencia-idE01A-0CC3-D631
person.identifier.ciencia-idF61A-1211-0B5C
person.identifier.orcid0000-0003-0107-9577
person.identifier.orcid0000-0001-6354-9437
person.identifier.ridP-2263-2015
person.identifier.scopus-author-id55462948300
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication51a54f2c-0a51-4f8d-8791-529ffb1610e4
relation.isAuthorOfPublicationbffeb3b9-2511-4cad-967b-82a01620cc61
relation.isAuthorOfPublication.latestForDiscovery51a54f2c-0a51-4f8d-8791-529ffb1610e4

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Testing the reliability of ct.pdf
Size:
1.19 MB
Format:
Adobe Portable Document Format