Publication
Performance of ex situ bismuth film rotating disk electrode in trace metal analysis by stripping chronopotentiometry: definition of the depletion regime and optimization of experimental parameters
dc.contributor.author | Rocha, L. S. | |
dc.contributor.author | Pereira, E. | |
dc.contributor.author | Duarte, A. C. | |
dc.contributor.author | Pinheiro, J. P. | |
dc.date.accessioned | 2013-12-03T14:40:51Z | |
dc.date.available | 2013-12-03T14:40:51Z | |
dc.date.issued | 2011 | |
dc.date.updated | 2013-11-26T16:15:58Z | |
dc.description.abstract | The potentiality of the ex situ deposited bismuth film electrode, allied to the rotation of a glassy carbon disk electrode (BiFE-RDE), was exploited in trace metal analyses of lead(II) and cadmium(II) by stripping chronopotentiometry (SCP). A single BiFE (6.2 nm film thickness) can be used for a 1-day term with no significant variation in the analytical signal. The limit of detection (3s) for a deposition time of 40 s and an oxidation current of 15 10 9 A was 1.5 10 8 M for Pb(II) and 3.0 10 8 M for Cd(II). BiFE-RDE was successfully applied to the direct SCP determination of lead(II) in a fresh water certified material. | por |
dc.identifier.citation | Rocha, L. S.; Pereira, E.; Duarte, A. C.; Pinheiro, J. P.Performance of Ex Situ Bismuth Film Rotating Disk Electrode in Trace Metal Analysis by Stripping Chronopotentiometry: Definition of the Depletion Regime and Optimization of Experimental Parameters, Electroanalysis, 23, 8, 1891-19, 2011. | por |
dc.identifier.doi | http://dx.doi.org/10.1002/elan.201100119 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.other | AUT: JPI01020; | |
dc.identifier.uri | http://hdl.handle.net/10400.1/3208 | |
dc.language.iso | eng | por |
dc.peerreviewed | yes | por |
dc.publisher | Wiley | por |
dc.subject | Bismuth film electrode | por |
dc.subject | Fresh water | por |
dc.subject | Heavy metals | por |
dc.subject | Stripping chronopotentiometry | por |
dc.subject | Thin mercury film electrode | por |
dc.title | Performance of ex situ bismuth film rotating disk electrode in trace metal analysis by stripping chronopotentiometry: definition of the depletion regime and optimization of experimental parameters | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 1900 | por |
oaire.citation.issue | 8 | por |
oaire.citation.startPage | 1891 | por |
oaire.citation.title | Electroanalysis | por |
oaire.citation.volume | 23 | por |
person.familyName | Pinheiro | |
person.givenName | José Paulo | |
person.identifier.orcid | 0000-0001-7925-9733 | |
person.identifier.rid | E-8402-2013 | |
person.identifier.scopus-author-id | 35838299700 | |
rcaap.rights | restrictedAccess | por |
rcaap.type | article | por |
relation.isAuthorOfPublication | 5caedbac-d2b5-4a86-91a7-083bf83edda3 | |
relation.isAuthorOfPublication.latestForDiscovery | 5caedbac-d2b5-4a86-91a7-083bf83edda3 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- n52 electroanalysis 23 (2011) 1891.pdf
- Size:
- 334.76 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: