Repository logo
 
Publication

Silicon strip detectors for two-dimensional soft X-ray imaging at normal incidence

dc.contributor.authorMendes, PR
dc.contributor.authorAbreu, MC
dc.contributor.authorBaldazzi, G
dc.contributor.authorBollini, D
dc.contributor.authorRodriguez, AEC
dc.contributor.authorDabrowski, W
dc.contributor.authorGarcia, AD
dc.contributor.authorGambaccini, M
dc.contributor.authorGiubellino, P
dc.contributor.authorGombia, M
dc.contributor.authorGrybos, P
dc.contributor.authorIdzik, M
dc.contributor.authorMarzari-Chiesa, A
dc.contributor.authorMontano, LM
dc.contributor.authorPrino, F
dc.contributor.authorRamello, L
dc.contributor.authorRodrigues, Susana
dc.contributor.authorSitta, M
dc.contributor.authorSousa, P
dc.contributor.authorSwientek, K
dc.contributor.authorTaibi, A
dc.contributor.authorTuffanelli, A
dc.contributor.authorWheadon, R
dc.contributor.authorWiacek, P
dc.date.accessioned2018-12-07T14:52:44Z
dc.date.available2018-12-07T14:52:44Z
dc.date.issued2003-08
dc.description.abstractA simple prototype system for static two-dimensional soft X-ray imaging using silicon microstrip detectors irradiated at normal incidence is presented. Radiation sensors consist of single-sided silicon detectors made from 300 mum thick wafers, read by RX64 ASICs. Data acquisition and control is performed by a Windows PC workstation running dedicated LabVIEW routines, connected to the sensors through a PCI-DIO-96 interface. Two-dimensional images are obtained by scanning a lead collimator with a thin slit perpendicular to the strip axis, along the whole detector size; the several strip profiles (slices) taken at each position are then put together to form a planar image. Preliminary results are presented, illustrating the high-resolution imaging capabilities of the system with soft X-rays. (C) 2003 Elsevier B.V. All rights reserved.
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.doi10.1016/S0168-9002(03)01646-2
dc.identifier.issn0168-9002
dc.identifier.urihttp://hdl.handle.net/10400.1/11189
dc.language.isoeng
dc.peerreviewedyes
dc.publisherElsevier Science Bv
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleSilicon strip detectors for two-dimensional soft X-ray imaging at normal incidence
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceAMSTERDAM, NETHERLANDS
oaire.citation.endPage339
oaire.citation.issue01-mar
oaire.citation.startPage333
oaire.citation.titleNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
oaire.citation.title4Th International Workshop On Radiation Imaging Detectors
oaire.citation.volume509
person.familyNameRodrigues
person.givenNameSusana
person.identifier.ciencia-id9D1A-6537-0383
person.identifier.orcid0000-0002-0329-4265
person.identifier.scopus-author-id55125292100
rcaap.rightsopenAccess
rcaap.typearticle
relation.isAuthorOfPublicationf7e806c8-708d-4caf-9b95-cfe9f3b06e8e
relation.isAuthorOfPublication.latestForDiscoveryf7e806c8-708d-4caf-9b95-cfe9f3b06e8e

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
H11189.pdf
Size:
533.53 KB
Format:
Adobe Portable Document Format