Thermal study of school buildings in winter conditions

dc.contributor.authorConceição, E. Z. E.
dc.contributor.authorLucio, M. M. J. R.
dc.date.accessioned2016-01-27T10:34:00Z
dc.date.available2016-01-27T10:34:00Z
dc.date.issued2008
dc.description.abstractIn this paper, a thermal study of a school building with real occupation levels in winter conditions is presented and a software that evaluates the air quality and simulates the thermal response of buildings with complex topology in steady-state and transient conditions is used, After validation, the numerical model is used, in the first phase, to evaluate the occupants' comfort levels in several spaces, while in the second phase two solutions, to improve acceptable thermal comfort and air quality levels (1) the electric air-heating systems, with predicted mean vote control, and (2) three solar collectors, placed instead of the roof area, used to heat the air in uncomfortable spaces are studied. The software is based on energy and mass balance integral equations that considers all conductive, convective, radiative and massic phenomena and internal heat generation in the building. In the radiative phenomena, which are very important in this region, all shading effects, incident solar radiation and radiative exchanges in all indoor and outdoor surfaces will be considered, and the mass phenomena, which are very important in thermal and air quality studies, internal mass generation, mass exchanges among compartments and between them and external environment will be considered. The considered school building, located in the south of Portugal, has three levels, 97 compartments, 1277 main bodies and 211 windows with simple transparent glass. This simulation took place on a winter day with clear sky and with 800 occupants. In this study, where a project of a school building with acceptable thermal and air quality levels is presented, the solar radiation (very intense in this region) will be used in order to reduce the school building's energy consumption levels. (C) 2007 Elsevier Ltd. All rights reserved.
dc.identifier.doihttps://dx.doi.org/10.1016/j.buildenv.2007.01.029
dc.identifier.issn0360-1323
dc.identifier.otherAUT: ECO01058;
dc.identifier.urihttp://hdl.handle.net/10400.1/7521
dc.language.isoeng
dc.peerreviewedyes
dc.publisherElsevier
dc.relation.isbasedonP-003-ZJC
dc.titleThermal study of school buildings in winter conditions
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage792
oaire.citation.startPage782
oaire.citation.titleBuilding and Environment
oaire.citation.volume43
person.familyNameConceição
person.givenNameEusébio
person.identifier.ciencia-id6317-FB21-9671
person.identifier.orcid0000-0001-5963-2107
person.identifier.ridI-7931-2015
person.identifier.scopus-author-id6603299150
rcaap.rightsrestrictedAccess
rcaap.typearticle
relation.isAuthorOfPublicationbd0b4c3b-bd28-4e29-ab0b-1ac167828d7f
relation.isAuthorOfPublication.latestForDiscoverybd0b4c3b-bd28-4e29-ab0b-1ac167828d7f

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
Thermal study of school buildings in winter conditions.pdf
Tamanho:
896.05 KB
Formato:
Adobe Portable Document Format