Repository logo
 
Publication

Scanned stripping chronopotentiometry of metal complexes: lability diagnosis and stability computation

dc.contributor.authorPinheiro, J. P.
dc.contributor.authorVan Leeuwen, H. P.
dc.date.accessioned2013-12-02T18:29:08Z
dc.date.available2013-12-02T18:29:08Z
dc.date.issued2004
dc.date.updated2013-11-26T16:49:05Z
dc.description.abstractA method is presented for analyzing the dynamic speciation features of metal complexes based on stripping chronopotentiometry at a scanned deposition potential (SSCP). The shift in the SSCP half-wave deposition potential, DEd;1=2, is straightforwardly related to the complex stability, K, irrespective of the degree of lability; the limiting wave height, s , quantifies the metal species accumulated in the electrode and thus depends on both the lability and mass transport properties of the metal complex species in solution. For complexes with a lower diffusion coefficient than the free metal ion, K calculated from DEd;1=2 will be the same as that derived from the relative s values so long as the system is fully labile. Discrepancies between DEd;1=2-derived and s -derived K values indicate loss of lability. We show that this approach is a sensitive indicator of lability, as illustrated by analysis of cadmium and lead binding by carboxylated nanospheres.por
dc.identifier.citationPinheiro, J. P.; Van Leeuwen, H. P. Scanned stripping chronopotentiometry of metal complexes: Lability diagnosis and stability computation, Journal of Electroanalytical Chemistry, 570, 1, 69-75, 2004.por
dc.identifier.doihttp://dx.doi.org/10.1016/j.jelechem.2004.03.016
dc.identifier.issn1572-6657
dc.identifier.otherAUT: JPI01020;
dc.identifier.urihttp://hdl.handle.net/10400.1/3199
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.subjectLabilitypor
dc.subjectStripping chronopotentiometrypor
dc.subjectScanned potentialpor
dc.subjectSSCPpor
dc.subjectKinetic currentspor
dc.subjectTrace metalspor
dc.subjectDynamic speciationpor
dc.titleScanned stripping chronopotentiometry of metal complexes: lability diagnosis and stability computationpor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage75por
oaire.citation.issue1por
oaire.citation.startPage69por
oaire.citation.titleJournal of Electroanalytical Chemistrypor
oaire.citation.volume570por
person.familyNamePinheiro
person.givenNameJosé Paulo
person.identifier.orcid0000-0001-7925-9733
person.identifier.ridE-8402-2013
person.identifier.scopus-author-id35838299700
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication5caedbac-d2b5-4a86-91a7-083bf83edda3
relation.isAuthorOfPublication.latestForDiscovery5caedbac-d2b5-4a86-91a7-083bf83edda3

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
n22_jec 570 (2004) 69-75.pdf
Size:
237.64 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: