Repository logo
 
Publication

What s new in the Visionaire system® in second-generation for TKA? a comparative study of accuracy, efficiency and functional results

dc.contributor.authorFontes, Ana Paula
dc.contributor.authorCintra, Rui Miguel
dc.contributor.authorGomes, Luis
dc.contributor.authorSousa, Joao Paulo
dc.date.accessioned2022-07-21T10:45:39Z
dc.date.available2022-07-21T10:45:39Z
dc.date.issued2022-04-25
dc.date.updated2022-07-20T16:52:10Z
dc.description.abstractBackground: The aim of the study was to analyze and compare the accuracy, efficiency and functional evolution between the first- and second-generation Patient-specific instrumentation (PSI). Methods: We report our experience in TKA using PSI Visionaire System® (Smith and Nephew®) in 456 procedures. The patients were divided into first- (N=272) and second-generation PSI design (N=184). For the accuracy was analyzed the mechanical results, namely Hip-knee-ankle (HKA) alignment post-TKA and outliers’ frequency; for the efficiency was analyzed the length time surgery, the length of stay and satisfaction, for the functional outcomes was compared the evolution at pain, range of motion, gait perimeter and the domains of the Western ontario and mcmaster osteoarthritis index (WOMAC). The t-test for independent samples was applied in the continuous numeric variables and Qui square tests in the dichotomic nominal variables. Statistical significance was p value<0.05. Results: The alignment of the femur worsened significantly in the second-generation (p=0.002), but the alignment of the tibia was improved (p=0.010). However, not enough to improve significantly the HKA. No significant differences were observed in the frequency of outliers. The length of stay decreased in the second-generation (<0.001). The functioning achieved at first and third months after surgery was lower in second-generation PSI; at first month in the pain and stiffness WOMAC (p=0.030; p>0.001) and in the third in WOMAC stiffness (p<0.001). Conclusions: The second-generation PSI of Visionaire system® improved the alignment of the tibia, but not the alignment of the femur. This change did not produce any improvements in functioning.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.18203/issn.2455-4510.intjresorthop20221117pt_PT
dc.identifier.issn2455-4510
dc.identifier.slugcv-prod-2994432
dc.identifier.urihttp://hdl.handle.net/10400.1/18055
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherMedip Academypt_PT
dc.subjectPatient-specific instrumentationpt_PT
dc.subjectTotal knee arthroplastypt_PT
dc.subjectTotal knee replacementpt_PT
dc.subjectFunctional outcomespt_PT
dc.subjectNavigation systempt_PT
dc.subjectVisionaire systempt_PT
dc.titleWhat s new in the Visionaire system® in second-generation for TKA? a comparative study of accuracy, efficiency and functional resultspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage302pt_PT
oaire.citation.issue3pt_PT
oaire.citation.startPage298pt_PT
oaire.citation.titleInternational Journal of Research in Orthopaedicspt_PT
oaire.citation.volume8pt_PT
person.familyNamede Almeida Fontes
person.givenNameAna Paula
person.identifier.ciencia-id6E12-B4BA-87AF
person.identifier.orcid0000-0002-4431-5229
rcaap.cv.cienciaid6E12-B4BA-87AF | Ana Paula de Almeida Fontes
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication00fe72a3-c82a-4726-bd5d-efeb7fb59650
relation.isAuthorOfPublication.latestForDiscovery00fe72a3-c82a-4726-bd5d-efeb7fb59650

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Whata__s_new_in_the_Visionaire_system_in_second-generation_for_TKA.pdf
Size:
191.59 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.49 KB
Format:
Item-specific license agreed upon to submission
Description: