Repository logo
 
Publication

Fatores que influenciam o tratamento de efluentes em Fito-Etar de leito de macrófitas: estudo de caso: Etar do concelho de Aljezur

datacite.subject.fosEngenharia e Tecnologia::Outras Engenharias e Tecnologiaspt_PT
dc.contributor.advisorTeixeira, Margarida Ribau
dc.contributor.authorLopes, Gessica Arianny da Silva
dc.date.accessioned2022-07-14T15:31:06Z
dc.date.available2022-07-14T15:31:06Z
dc.date.issued2021-12-15
dc.description.abstractAtualmente as estações de tratamento de águas residuais (ETAR) com áreas húmidas construídas (Constructed Wetlands - CWs) apresentam-se como uma solução ambientalmente sustentável e eficaz no tratamento de águas residuais domésticas de pequenos aglomerados populacionais, devido aos seus baixos custos de implementação e operação, menores exigências energéticas e de manutenção, e elevada eficiência de remoção de contaminantes. Neste sentido, este trabalho tem por objetivo identificar e validar os fatores que influenciam a qualidade dos efluentes tratados em ETAR com CWs. Em resposta a estas questões foram determinadas as eficiências de tratamento de cinco ETAR no sul de Portugal, com tratamento primário, constituído por fossa séptica, e CWs. Os resultados demonstraram que a utilização deste tipo de sistemas pode ser exequível nos dias atuais, com remoções de Carência Química de Oxigénio (CQO) a variar entre 78,8 – 93,9 %, Carência Bioquímica de Oxigénio (CBO5) entre 89,7 – 97,0%, Sólidos Suspensos Totais (SST) entre 64,5 – 97,9%, Azoto total (Ntotal) entre 19,8 – 48,5 %, e Fósforo total (Ptotal) entre 6,3 – 46,5%. Através deste trabalho foi possível verificar que a remoção da matéria orgânica esteve relacionada principalmente com a eficiência de remoção da fossa séptica e com o escoamento uniforme do caudal ao CWs. A remoção do SST esteve associada à filtração física e à sedimentação, onde os processos físicos de remoção dos gradados e a extração das lamas no tratamento primário foram os principais fatores que afetaram a remoção desse contaminante. Também se verificou que a remoção do azoto e do fósforo esteve relacionada com a diversidade de plantas no CWs e com a capacidade de interceptação do material particulado no meio de enchimento. Por fim, concluiu-se que apesar do bom funcionamento destes sistemas de tratamento, a sua estrutura deverá ser modificada por forma a aumentar o tempo de vida e possibilitar a manutenção e operação efetivas.pt_PT
dc.description.abstractCurrently, wastewater treatment plants (WWTPs) with built-up constructed wetlands (CWs) present themselves as an environmentally sustainable and effective solution in the treatment of domestic wastewater from small population agglomerates, due to their low implementation and operation costs, lower energy and maintenance requirements, and high efficiency in removing contaminants. In this sense, this work aims to identify and validate the factors that influence the quality of effluent treated in WWTPs with CWs. In response to these questions, the treatment efficiencies of five WWTPs in southern Portugal with septic tank as primary treatment were determined. Results demonstrated that the use of this type of system is feasible nowadays, with removals of the Chemical Oxygen Demand (COD) between 78,8 – 93,9 %, Biochemical Oxygen Demand (BOD5) 89,7 – 97,0 %, Total Suspended Solids (SST) 64,5 – 97,9 %, Total Nitrogen (Ntotal) 19,8 – 48,5 %, and Total Phosphorus (Ptotal) 6,3 – 46,5 %. According to these results, the removal of organic matter was mainly related with the efficiency of the septic tank and the uniform flow to the plant bed. The removal of SST was associated with physical filtration and sedimentation, where the physical processe of removing the harrows and the sludge removal in the primary treatment were the main factors that affected the removal of this contaminant. Removal of nitrogen and phosphorus was related to plant diversity in CWs and the ability to intercept particulate matter in the filling medium. At the end of this work, it was also possible to concluded that despite the good performance of these treatment systems, their structure should be modified to increase the lifespan and enable effective maintenance and operation.pt_PT
dc.identifier.tid202914160pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.1/18004
dc.language.isoporpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectÁgua residualpt_PT
dc.subjectTratamento de águapt_PT
dc.subjectMacrófitaspt_PT
dc.subjectÁreas húmidas construídaspt_PT
dc.subjectAljezurpt_PT
dc.titleFatores que influenciam o tratamento de efluentes em Fito-Etar de leito de macrófitas: estudo de caso: Etar do concelho de Aljezurpt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.grantorUniversidade do Algarve. Instituto Superior de Engenharia
thesis.degree.levelMestre
thesis.degree.nameMestrado em Ciclo Urbano da Águapt_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Dissertação_Gessica Lopes. corrigido 21.12.pdf
Size:
2.17 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.46 KB
Format:
Item-specific license agreed upon to submission
Description: