Publication
Performance assessment of polymer based electrodes for in vitro electrophysiological sensing: the role of the electrode impedance
dc.contributor.author | Medeiros, Maria C. R. | |
dc.contributor.author | Mestre, Ana L. G. | |
dc.contributor.author | INÁCIO, PEDRO | |
dc.contributor.author | Santos, João M. L. | |
dc.contributor.author | Araújo, Inês | |
dc.contributor.author | Bragança, José | |
dc.contributor.author | Biscarini, Fabio | |
dc.contributor.author | Gomes, Henrique L. | |
dc.date.accessioned | 2017-04-07T15:57:18Z | |
dc.date.available | 2017-04-07T15:57:18Z | |
dc.date.issued | 2016 | |
dc.description.abstract | Conducting polymer electrodes based on poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) are used to record extracellular signals from autonomous cardiac contractile cells and glioma cell cultures. The performance of these conducting polymer electrodes is compared with Au electrodes. A small-signal impedance analysis shows that in the presence of an electrolyte, both Au and polymer electrodes establish high capacitive double-layers. However, the polymer/electrolyte interfacial resistance is 3 orders of magnitude lower than the resistance of the metal/electrolyte interface. The polymer low interfacial resistance minimizes the intrinsic thermal noise and increases the system sensitivity. However, when measurements are carried out in current mode a low interfacial resistance partially acts as a short circuit of the interfacial capacitance, this affects the signal shape. | |
dc.identifier.doi | 10.1117/12.2237659 | |
dc.identifier.isbn | 978-1-5106-0280-9 | |
dc.identifier.issn | 0277-786X | |
dc.identifier.uri | http://hdl.handle.net/10400.1/9670 | |
dc.language.iso | eng | |
dc.peerreviewed | yes | |
dc.publisher | SPIE | |
dc.relation.isbasedon | WOS:000393153000001 | |
dc.title | Performance assessment of polymer based electrodes for in vitro electrophysiological sensing: the role of the electrode impedance | |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.conferencePlace | San Diego, CA | |
oaire.citation.endPage | UNSP 994408 | |
oaire.citation.startPage | UNSP 994404 | |
oaire.citation.title | Organic Sensors and Bioelectronics IX. Proceedings of SPIE | |
oaire.citation.volume | 9944 | |
person.familyName | INÁCIO | |
person.familyName | Pombinho de Araújo | |
person.familyName | Bragança | |
person.familyName | Gomes | |
person.givenName | PEDRO | |
person.givenName | Inês Maria | |
person.givenName | José | |
person.givenName | Henrique Leonel | |
person.identifier | 2001885 | |
person.identifier | F-4703-2012 | |
person.identifier.ciencia-id | 1510-2B36-5ED1 | |
person.identifier.ciencia-id | D11F-D4CA-2947 | |
person.identifier.ciencia-id | AC1D-FA9D-F66F | |
person.identifier.orcid | 0000-0003-1986-7918 | |
person.identifier.orcid | 0000-0002-2438-0111 | |
person.identifier.orcid | 0000-0001-9566-400X | |
person.identifier.orcid | 0000-0003-3664-4740 | |
person.identifier.scopus-author-id | 55938897300 | |
person.identifier.scopus-author-id | 56271084100 | |
person.identifier.scopus-author-id | 6602220001 | |
person.identifier.scopus-author-id | 7005305880 | |
rcaap.rights | openAccess | |
rcaap.type | article | |
relation.isAuthorOfPublication | 127aefaa-ee35-4706-9e3b-ee06fa44bb4a | |
relation.isAuthorOfPublication | 1d0c21f4-0f4b-4589-8412-fe1079419774 | |
relation.isAuthorOfPublication | 27334e02-e955-4939-b9b5-bdee5b5f9328 | |
relation.isAuthorOfPublication | 6da677b9-927f-423d-8657-448a0dccb67c | |
relation.isAuthorOfPublication.latestForDiscovery | 1d0c21f4-0f4b-4589-8412-fe1079419774 |
Files
Original bundle
1 - 1 of 1