Publication
Validate a method for the determination of Cadmium and Lead by using Stripping Chronopotentiometry (SCP) obtained by thin mercury film deposited on rotating disk electrode (TMF-RDE)
datacite.subject.fos | Ciências Naturais::Ciências da Terra e do Ambiente | pt_PT |
dc.contributor.advisor | Pinheiro, José Paulo | |
dc.contributor.author | Islam, Samia | |
dc.date.accessioned | 2018-04-17T15:56:43Z | |
dc.date.available | 2018-04-17T15:56:43Z | |
dc.date.issued | 2012 | |
dc.date.submitted | 2012 | |
dc.description | Dissertação de Mestrado, Qualidade em Análises, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2012 | |
dc.description.abstract | Neste trabalho, um novo método foi desenvolvido e validado para a determinação de Cd e Pb em água da torneira, com base num eléctrodo de disco rotativo (RDE-TMF), utilizando cronopotenciometria de redissolução (SCP). A espessura do TMFE foi determinada foi (1,46 ± 0,06) x 10-3 C para um intervalo de confiança de 95%. O procedimento foi composto por: potencial de deposição - 0,78 V; tempo de deposição 90 s; corrente de redissolução 5 μA e agitação de 1500 rpm. Para ambos os metais, a linearidade obtida dentro do intervalo de concentração de (2,5 × 10-9 a 1 × 10-7 M) percentagens de recuperação de foram 111 ± 15% e 103 ± 11% foram obtidos para o cádmio e para o chumbo, respectivamente (com base nos resultados dos materiais de referência certificados). Os limites de detecção obtidos para o Cd e Pb foram de (4,7 ± 3,8) x 10-10 M e (3,2 ± 0,4) x 10-10 M, respectivamente, e foram também obtidos valores de CV < 8%. O método analítico SCP revelou-se eficaz para a determinação de cádmio e chumbo na água da torneira utilizando o filme fino de mercúrio depositado sob um eléctrodo de disco rotativo. | pt_PT |
dc.description.abstract | A new validated method for Cd and Pb determinations in tap water, based on rotating disk electrode (TMF-RDE), using stripping chronopotentiometry (SCP), was developed. The TMFE thickness determined was determined at (1.46 ± 0.06) × 10-3 C for 95% confidence interval. The procedure comprised: deposition potential - 0.78 V; deposition time 90 s; stripping current 5 μA and stirring rate 1500 rpm. For both metals linearity was achieved within the concentration range of (2.5 × 10-9 to 1 × 10-7 M) with a high value of the regression coefficient based on the results of the Certified Reference Materials the trueness values in terms of % recovery were found to be 111 ± 15 % and 103 ± 11 % for cadmium and lead respectively. Detection limits of (4.7 ± 3.8) × 10-10 M and (3.2 ± 0.4) × 10-10 M were obtained for Cd and Pb, respectively, and CV values < 8% were observed. SCP was found to be an effective method for cadmium and lead in tap water by using thin mercury film on rotating disk electrode. | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.1/10623 | |
dc.language.iso | eng | pt_PT |
dc.subject | Análises laboratoriais | pt_PT |
dc.subject | Controlo da qualidade | pt_PT |
dc.subject | Água potável | pt_PT |
dc.subject | Cádmio | pt_PT |
dc.subject | Chumbo | pt_PT |
dc.title | Validate a method for the determination of Cadmium and Lead by using Stripping Chronopotentiometry (SCP) obtained by thin mercury film deposited on rotating disk electrode (TMF-RDE) | pt_PT |
dc.type | master thesis | |
dspace.entity.type | Publication | |
rcaap.rights | restrictedAccess | pt_PT |
rcaap.type | masterThesis | pt_PT |
thesis.degree.discipline | Qualidade em análises | |
thesis.degree.grantor | Universidade do Algarve. Faculdade de Ciências e Tecnologia | |
thesis.degree.level | Mestre | |
thesis.degree.name | Mestrado em Qualidade em Análises | pt_PT |