Repository logo
 
Publication

Validate a method for the determination of Cadmium and Lead by using Stripping Chronopotentiometry (SCP) obtained by thin mercury film deposited on rotating disk electrode (TMF-RDE)

datacite.subject.fosCiências Naturais::Ciências da Terra e do Ambientept_PT
dc.contributor.advisorPinheiro, José Paulo
dc.contributor.authorIslam, Samia
dc.date.accessioned2018-04-17T15:56:43Z
dc.date.available2018-04-17T15:56:43Z
dc.date.issued2012
dc.date.submitted2012
dc.descriptionDissertação de Mestrado, Qualidade em Análises, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2012
dc.description.abstractNeste trabalho, um novo método foi desenvolvido e validado para a determinação de Cd e Pb em água da torneira, com base num eléctrodo de disco rotativo (RDE-TMF), utilizando cronopotenciometria de redissolução (SCP). A espessura do TMFE foi determinada foi (1,46 ± 0,06) x 10-3 C para um intervalo de confiança de 95%. O procedimento foi composto por: potencial de deposição - 0,78 V; tempo de deposição 90 s; corrente de redissolução 5 μA e agitação de 1500 rpm. Para ambos os metais, a linearidade obtida dentro do intervalo de concentração de (2,5 × 10-9 a 1 × 10-7 M) percentagens de recuperação de foram 111 ± 15% e 103 ± 11% foram obtidos para o cádmio e para o chumbo, respectivamente (com base nos resultados dos materiais de referência certificados). Os limites de detecção obtidos para o Cd e Pb foram de (4,7 ± 3,8) x 10-10 M e (3,2 ± 0,4) x 10-10 M, respectivamente, e foram também obtidos valores de CV < 8%. O método analítico SCP revelou-se eficaz para a determinação de cádmio e chumbo na água da torneira utilizando o filme fino de mercúrio depositado sob um eléctrodo de disco rotativo.pt_PT
dc.description.abstractA new validated method for Cd and Pb determinations in tap water, based on rotating disk electrode (TMF-RDE), using stripping chronopotentiometry (SCP), was developed. The TMFE thickness determined was determined at (1.46 ± 0.06) × 10-3 C for 95% confidence interval. The procedure comprised: deposition potential - 0.78 V; deposition time 90 s; stripping current 5 μA and stirring rate 1500 rpm. For both metals linearity was achieved within the concentration range of (2.5 × 10-9 to 1 × 10-7 M) with a high value of the regression coefficient based on the results of the Certified Reference Materials the trueness values in terms of % recovery were found to be 111 ± 15 % and 103 ± 11 % for cadmium and lead respectively. Detection limits of (4.7 ± 3.8) × 10-10 M and (3.2 ± 0.4) × 10-10 M were obtained for Cd and Pb, respectively, and CV values < 8% were observed. SCP was found to be an effective method for cadmium and lead in tap water by using thin mercury film on rotating disk electrode.pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.1/10623
dc.language.isoengpt_PT
dc.subjectAnálises laboratoriaispt_PT
dc.subjectControlo da qualidadept_PT
dc.subjectÁgua potávelpt_PT
dc.subjectCádmiopt_PT
dc.subjectChumbopt_PT
dc.titleValidate a method for the determination of Cadmium and Lead by using Stripping Chronopotentiometry (SCP) obtained by thin mercury film deposited on rotating disk electrode (TMF-RDE)pt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsrestrictedAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.disciplineQualidade em análises
thesis.degree.grantorUniversidade do Algarve. Faculdade de Ciências e Tecnologia
thesis.degree.levelMestre
thesis.degree.nameMestrado em Qualidade em Análisespt_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Final Thesis of Samia.pdf
Size:
1.75 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.41 KB
Format:
Item-specific license agreed upon to submission
Description: